SPECIFICATIONS
TERRACES,
CHAJJAS, CANOPIES, STAIRCASES, GUTTERS ETC
Our treatment starts
directly over the RCC slab with laying over our polymerised waterproof
brickbat coba to provide necessary gradient of 1 in 120 (1 inch in
10 ft.) for the easy flowaway of rainwater. Finally the brickbat coba
is covered with our C & F Polymer jointless waterproof plaster
finished smooth with trowel in cement colour, marked into 300 mm (1
ft.) false squares. This treatment is carried along the inner
side of parapet and/or other adjoining wall upto a height of about
300 mm(1 ft) in the shape of a round vata. The average thickness of
this treatment is about 100 mm (4 in) with a minimum thickness at
water outlets being 75 mm (3 in). This surface is hard and tough,
and suitable for all normal domestic activities.
BASEMENT
& OTHER UNDERGROUND STRUCTURES (EXISTING STRUCTURES)
In the case of existing basements
or any other underground structures where there is no access available
from the outside and below the raft slab, we treat from inside with
our injection C & F Grouting and polymer box methods.
The treatment starts with giving injections into the structure,
as and where found necessary by us. Thereafter, our waterproof later,
finished smooth with trowel in cement, is laid on the floor and continued
on the side and partition walls, columns etc. for their full height
or 300 mm (1 ft) above ground or other adjoining apron level.
the average thickness of this treatment is about 65 mm (21/2
in) on the floor and 25 mm (1 in) on the walls.
BASEMENT
& OTHER UNDERGROUND STRUCTURES (NEW STRUCTURES)
The treatment starts
over the leveling course of about 150 mm (6 in) thick plain cement
concrete (PCC) laid even with smooth surface finished with wooden
trowel by the owners on well-compacted soil or rubble packing, as
the case may be, in accordance with the strata. On the PCC we provide
our cement based C & F waterproof layer. This surface is then
superimposed by the owners with RCC raft slab designed to withstand
the uplift pressure of the subsoil water. After completion of the
raft slab and side walls, the said C & F waterproof layer is continued
along the outer surface of the walls upto 300 mm(1 ft) above ground
or other adjoining apron level. The average thickness of this treatment
is about 75 mm(3 in) on the floor, and 32 mm(11/4in)
on the walls. The excavation of the sides around the wall is then
filled in with soft earth by the owners. By this method the entire
structure is encased by our treatment to turn into a sealtight box
and the attacking subsoil water does not find any access into it.
WATER
STORAGE TANKS
After the plumbing work
is completed and the normal plaster to the outer surface is provided
by the owners through the main contractor, the treatment starts with
giving injections into the structure , as and where found necessary
by us. There after our C & F waterproof layer, finished smooth
with trowel in cement,is laid on the floor and continued on the side
and partition walls upto their full height. The average thickness
of this treatment is 65 mm(21/2 in) on the floor
and 25 mm (1 in) on the walls.
WALLS
C & F Polyplaster
The treatment starts with giving injections
wherever we find necessary in-between the joints of RCC beams, columns,
pardi and brickwork, to fill up the gap and joint. Then the surface
is covered with out special C & F water proof plaster in
three coats finished in sand faced texture. The average thickness
of this treatment is about 25 mm (1 in)
WCS,
SANITARY BLOCK, KITCHENS, WASHING PLACES, ETC.
Before our work is started, all
cutting or chasing in the floor and/or walls, and all the plumbing
work should be completed by the plumber and the normal plaster to
the ceiling and the upper part of walls provided by the owners through
the main contractor.
First
we fill in the depressed or sunk portions of the WCs and Bathrooms,
etc with our brickbat coba with necessary gradient for the easy flow
away of water towards the nahani trap or soil pan, the surface being
finished suitably with 18mm (3/4 in) thick C
& F waterproof plaster, in order to receive tiles to be laid by
the owners. The said C & F waterproof plaster shall then be continued
on the walls above the floor for a height of 1 metre (31/4
ft). In the shower area of the bathrooms, the treatment shall be for
the full height of the walls.
WATER-PROOFING
WITH THE STRENGTH OF POLYGUNTING
C & F Polygunite
The treatment starts with giving injections
into the structure as and where found necessary by us. Thereafter
the entire surface will be covered with our C & F Polygunite waterproof
layer using guniting process (with or without IRC fabric or reinforcement
as the case may be).
Finally
the surface will be finished either smooth, or in sand-faced texture,
or rough if it is desired to be covered with decorative tiles as the
case may be.
The
average thickness of this treatment is about 50 mm (2 in) on the floor
and 35 mm (11/4) on the walls.
NOTE:
We also offer non conventional treatments based on Modified Polymers
Epoxies, Poly-urethanes, FRP Etc.
|